Module loading Automated
Module dimensions Maximum 265 cm x 137 cm
Cycle time <21 seconds with all tests
Automation Module movement & contacting
Repeatability Standard deviation < 0.1 %
IEC 90604-9 Ed.3 Class A+A+A+
Flash tube lifetime 750 000 measurements
High eff. modules Capacitance Compensation (CAC) method, HJT, TOPCon, IBC etc.
Measurement scales 1–100 V & 0.5-25 A (other scales on request), Accuracy < ±0.2 %
Voltage sweep Isc -> Voc, Voc -> Isc, With single flash
EL Imaging 250 µm per pixel
Bypass diode test Functionality test, Acc. IEC 61215-2